BlueGate 20KVA Online UPS LF

New

FEATURES
Suitable for IT equipment: network, servers etc
High frequency and double conversion of online technology
Fully digitized microprocessor control
Wide input voltage range
LCD display
UPS start-up without a battery; Cold start
Advanced battery management
Automatic battery charging in UPS off mode
Lightning and surge protection
Short circuit and overload protection
Fan speed auto control when loads vary
Network/fax/modem surge protection
Optional extension battery pack
Battery voltage display
Load capacity display
EMI/RFI noise filter
Smart RS232 communication with monitoring software

Compare
SKU: REBLONU20kvaLFi Category:

The Blue Gate three-phase online UPS series, featured with cabinet built-in batteries, making ready to use. DSP Control, Programmable battery voltage, intelligent charge mode with powerful battery charger, is an ideal budget-concerned solution to your server, bank, industrial equipment, internet data centre, telecom, IT equipment and other mission-critical application.

Check out this our product : bluegate-5-5kva-24v-inverter-pure-sine-wave/

Here are more Renewable Energy Product For You:BlueGate 1.2KVA UPS (BG 1200).BlueGate 2.0KVA UPS( BG2000), BlueGate 1.5HP Split Unit Air, BlueGate 1.5kva-24V Solar Inverter, BlueGate 10KVA -(192V) Online Inverter, BlueGate 4KVA UPS. Pure Sine Wave 4000VA, Bluegate 5.5KVA-24V Inverter, BlueGate Lucan 200AH/12v BATTERY Deep CycleAnd Many More 

 

BLUE GATE 3p UPS Technical Specifications

Three-phase input three-phase output

  
Rated capacity(VA)20KVA
Active power(W)18KW
INPUT
Voltage Range 380/400/415Vac (-25%~+20%)  Three-phase
Frequency Range50/60Hz±5Hz auto-identification
Power Factor>0.8(no filter)     >0.9(with filter)
OUTPUT
Voltage Range 380/400/415Vac ±1%
Rated output current30A
FrequencyAuto learning
Frequency stability(battery mode) 50/60Hz±0.05%
WaveformPure Sinewave
Power Factor0.9(lag)
Total harmonic distortion<3% (linear load)  /  <5%(nonlinear load)
Overload capacity105%≤60min <110%   /  110%≤10min<125%
Crest Factor3:1 (max)
Efficiency89%
Transfer time (Line mode, Battery mode)0ms
Bypass
Rated voltage380/400/415Vac  (3-Phase,4 Wires)
Voltage protection range -40%~+20%
Rated frequency50/60Hz
Frequency protection range±20%
Transfer time 0ms/1ms
Overload capacity(In)15In, 10ms 5In, 5s
Battery
Voltage (VDC) 384VDC
panel
LEDinput, inverter, bypass, battery and output
LCDinput and output voltage, frequency, power factor, battery voltage,  battery current and status, load percentage, UPS status, history record, setting
Communication
interfaceDry contact, RS232, RS485, SNMP card slot
Working environment
Running Temperature 0~40℃
Relative humidity0~95% ( without condensing)
Storage temperature-25℃~55℃
Noise at 1<63dB
Weight50 kg